Model PI51 & PI52 - PID Detector

- The photoionization detector (PID) is used for the measurement of low (ppb) organic and inorganic species that can be ionized by the UV lamp (9.5, 10.6 & 11.7). Nearly 20,000 of these detectors have been sold worldwide since it was first released by HNU Systems in 1976. It has been used for the measurement of VOC’s in water (EPA method 602, EPA Method 50--, EPA Method SW846…, numerous OSHA methods), quality control… There are two Models that are described below:
- The Model PI52 has a PID, a power supply for the lamp and bias and an electrometer. The electrometer output is 0-10 VDC. The customer needs a separate ADC channel to feed the signal into the GC’s data system. Alternately, PID Analyzers sells a data system (Model 50) that will feed the signal into a separate PC.
- The Model PI51 has a PID and a power supply for the lamp and bias. Here, the customer uses the electrometer (FID type with a positive bias) already in the Gas chromatograph. This should already have the ADC connection to the customer GC data system.
- The PID is one of the most sensitive detectors available for VOC’s. It has the widest dynamic range of any detector available (108) and does not require any support gases except the carrier.
- Get a Quote now!
Want more information? Learn more by reading our brochure! Open PDF File | Download PDF | Back to Laboratory
Specifications
Species measured: | Detection limit: | Range: | Detector: |
Organics (VOCs) and inorganic species that can be ionized by the UV lamp (9.5, 10.6, 11.7) |
<0.5 ppb of benzene | > 5 x 107 | 2.5'' D x 5.5'' L |
Electronics enclosure (PI52): | Electronics enclosure (PI51): | Power consumption: | Dimensions: |
Weight: 3 lbs. Size: -'' W x -'' L x -'' H |
Weight: 0.40 lbs Size: 4'' W x 5'' D x 1.25''H |
< 2 amps @ 115V | 10'' L x 3'' W x 2.25'' D |
Instrument operating conditions: | |||
5-40 degrees C, 0-95% RH (non-condensing). |
Features
Easy to install | Selectivity | Wide linear dynamic range | |
Improves separations and analysis of trace species. | > 107 | 50-200 times more sensitive than the FID | |
High sensitivity | Adaptability | Non destructive | Used by environmental agencies worldwide |
pg or sub pg detection limits - most sensitive PID available | Is readily adaptable to any chromatograph. | Detectors can be run in-series. | |
Display (PI52 only) | ADC | Programmable Voltage output | |
Our 2 line by 16 character display can be backlit; used for range and background readings. | Our 16 bit ADC provides a resolution of 1 part in 64,000 and our signal algorithm minimizes noise by signal averaging in the msec range | 0-10VDC (PI52 only) |
Want more information? Learn more by reading our brochure! Open PDF File | Download PDF | Back to Laboratory